1 symbols used, 2 data for the entry, 1 volume flow – Lenze DSD User Manual

Page 179: 2 pressure increase, 3 efficiency of the fan, 4 fan rated speed, 7applications

Advertising
background image

Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23

179

7

Applications

7.19

Fan

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.19.1.1

Symbols used

7.19.2

Data for the entry

7.19.2.1

Volume flow

7.19.2.2

Pressure increase

7.19.2.3

Efficiency of the fan

7.19.2.4

Fan rated speed

Symbol

Description

Dimension unit

J

add

Additional moment of inertia

kgm

2

M

App

Torque of the application

Nm

M

rated

Rated torque of the fan

Nm

n

rated

Rated speed of the fan

rpm

P

Power of the medium

kW

P

Vlt

Required power of the fan

kW

Q

Volume flow

m

3

/s

Δp

Pressure increase

N/m

2

η

Vlt

Efficiency of the fan

Symbol

Description

Q

Volume of the fluid to be transported per time unit

Symbol

Description

Δp

Pressure difference between intake and outlet

Symbol

Description

η

Vlt

Fan efficiency (see fan data sheet)

Symbol

Description

n

rated

Rated speed of the fan (see fan data sheet)