11 drive dimensioning – Lenze DSD User Manual

Page 335

Advertising
background image

Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23

335

11

Drive Dimensioning

11.4

Lenze gearbox selection

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Alternating load or pulsating load?
According to the intensity of the periodically occurring alternating load, the alternating load

factor k

alt

is in the range of 1 ... 1.4.

• In the case of a symmetrical alternating load M

alt,out

= M

max,out

, the alternating load

factor k

alt

is 1.4.

• An alternating load without sign reversal (no torque reversal) is a pulsating load. The alternat-

ing load factor for pulsating loads is k

alt

= 1.

[11-12] Different torque characteristics at the output end of the gearbox

• Pulsating load

• The torque alternates between two values without sign re-

versal

• Alternating load factor k

alt

= 1

• Pulsating load

• The torque changes from 0 to the max. value without sign

reversal

• Alternating load factor k

alt

= 1

• Alternating load

• Torque reversal with sign reversal
• Alternating load factor k

alt

> 1 (here approx. 1.13)

M

out

t

M

max,out

M

alt,out

t

M

out

M

max,out

t

M

out

M

max,out

M

alt,out

Advertising