Components in the DC bus

12.3

9400 regenerative power supply module

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

12.3.2

Utilisation

The simulation of device-internal monitoring functions serves for the evaluation of the power de-

mand by DSD and the determination of the utilisation of the power supply module.
Regenerative power supply modules 9400 can be connected in parallel. The diagram shows the val-

ues for all the devices connected in parallel.

[12-2] Regenerative power supply module 9400 diagram: utilisation

Description
P

sum

(t)

Total power in the DC bus over time

P

mot,imp

DC pulse power in motor mode, relevant for the short-time thermal utilisation of the power

supply module

P

mot,av

Average DC power at the power supply module

P

mot,N

Permissible DC continuous power in supply mode, dependent on the mains choke and mains

voltage

P

N,gen,red

Permissible DC continuous power in regenerative feedback mode, dependent on the mains

choke and mains voltage

P

mot,max

Max. permissible power in regenerative feedback mode

P

gen,max,red

Max. permissible DC power in regenerative feedback mode without support of brake transistor

P

gen,max,Brm

Max. permissible DC power in regenerative feedback with support of brake transistor

A

Sup

(P

max

)

Utilisation of the regenerative power supply module, relative to the max. power in the DC bus

A

Sup

(P

av

)

Utilisation of the regenerative power supply module, relative to the continuous power in the

DC bus

A

Sup

(P

imp

)

Utilisation of the regenerative power supply module, relative to the pulse power in the DC bus

A

Sup

(P

gen,max

)

Utilisation of the regenerative power supply module without brake chopper, relative to the

max. regenerative power

A

Sup,Brm

(P

gen,max

) Utilisation of the regenerative power supply module with brake chopper, relative to the max.

regenerative power

Advertising