18

Drive dimensioning messages

18.7

Feedback

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

18.7

Feedback

18.7.1

Inverter/feedback combination not possible

18.7.2

No feedback selected

18.7.3

Feedback system is not checked

Note!

The operation of the feedback system on the selected inverter is not possible.

Cause

Effects

Possible remedies

The feedback system selected cannot

be connected to the inverter.

Servo inverters cannot be operated

without feedback.

Use a different feedback system.

• If the feedback is not to be evalu-

ated by the inverter (e. g. feed-

back for slave drive), this conflict

can be ignored (not in the case of

servo inverters).

• Convert the output signal of the

feedback system into a suitable

signal.

Note!

The inverter requires a speed feedback for the control process selected.

Cause

Effects

Possible remedies

A motor without feedback was se-

lected, although the inverter requires

a feedback system for the motor con-

trol.

Possibly the inverter cannot be oper-

ated.

Select the "Feedback" option in the

dimensioning step "Structure of the

drive axis/mechanical".

Note!

Checking the inverter-encoder evaluation is not possible. Check manually whether the inverter is able to

evaluate the feedback system of the motor.

Cause

Effects

Possible remedies

The user motors are not provided

with detailed information on the

feedback system.

Checking the inverter-encoder evalu-

ation is not possible in DSD.

Check the inverter-encoder evalua-

tion manually.