Applications

7.22

Winding drive for rewinder/unwinder

222

Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.22.7.12 Downtime 2

7.22.7.13 Downtime 3

Parameter

Description

t

0.2

Downtime after the deceleration phase while the max. tensile force F

max

still acts on the wind-

ing material.

• Condition: CINH = 0

CINH

Controller locked

F

Tensile force of the winding drive

T

Cycle of one winding process

t

0.1

Downtime 1

t

0.2

Downtime 2

t

0.3

Downtime 3

v

Line speed

T

v

t

t

0,1

t

0,2

t

0,3

F

t

1

t

CINH

Parameter

Description

t

0.3

Downtime after the winding process during which no tensile force (F

max

= 0) acts on the wind-

ing material.

• The controller is always inhibited during downtime 3. The thermal load of the inverter and

the motor is reduced.

CINH

Controller locked

F

Tensile force of the winding drive

T

Cycle of one winding process

t

0.1

Downtime 1

t

0.2

Downtime 2

t

0.3

Downtime 3

v

Line speed

T

v

t

t

0,1

t

0,2

t

0,3

F

t

1

t

CINH