16 field weakening factor kf > as winding ratio q, Field weakening factor k, 18 drive dimensioning messages – Lenze DSD User Manual

Page 460

Advertising
background image

18

Drive dimensioning messages

18.5

Lenze motor

460

Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

18.5.16

Field weakening factor k

f

> as winding ratio q

Warning!

The field weakening factor k

f

is xxx.

The winding ratio q is yyy.

For an optimally adapted drive, k

f

must be < q.

Cause

Effects

Possible remedies

The field weakening factor k

f

entered

is greater than the winding ratio q.

The drive solution is not optimal with

regard to the utilisation of the

torque-speed requirement.

Check the torque-speed requirement

in the M-n characteristic of the mo-

tor, or set k

f

< q.

Advertising