Drive Dimensioning

11.6

Inverters

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.6.2

Preselection

In the following subchapters the parameters for the preselection of the inverter are described.

11.6.2.1

Motor output

11.6.2.2

Design

11.6.2.3

Switching frequency

According to the inverter, different settings of the switching frequency can be carried out. The

switching frequency can be selected between "variable" or "fixed".

• If a variable switching frequency is used, the respective maximum available switching frequen-

cy is specified. However, this switching frequency is not reached if the inverter is subjected to

higher loads.

• Depending on the modulation mode of the switching frequency, a power-optimised or loss-op-

timised operation of the inverter can be carried out.

Symbol

Description

• Single axis

• Double axis

Symbol

Description

• BaseLine

• StateLine

• HighLine

• TopLine

Symbol

Description

f

ch,set

Switching frequency of the inverter

• At higher switching frequencies, acoustic motor noises and controller output currents are re-

duced. With a decreasing switching frequency, however, the losses in the motor increase.

• The preselection in the DSD corresponds to the Lenze setting of the inverter selected.

• Select the switching frequency at which the inverter is to be actuated.

• According to the selection, the respective rated data is displayed in the selection table.

• If the drive is to be actuated with a variable switching frequency, the max. possible output

current can only be reached with the lowest switching frequency.

• For inverters with a variable switching frequency in the Lenze setting, the lowest switching

frequency is to be selected.

Note!

Derating for the motor

• If the selected switching frequency is too low for the motor, a derating must be carried

out.