2 central mains supply via power supply module, 7applications – Lenze DSD User Manual

Page 187

Advertising
background image

Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23

187

7

Applications

7.21

Dimension the multi-axis system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Multi-axis application

[7-185] Multi-axis application with supply/feedback

7.21.2.2

Central mains supply via power supply module

[7-186] Central mains supply via power supply module

Excessive electrical energy (braking energy) is made available to the drive axes in the DC-bus con-

nection.

• The arrangement can be dimensioned in the DSD.

• The drive axes can be each dimensioned separately in the DSD.
• In the "Dimension the multi-axis system" application you combine the drive axes and dimen-

sion the power supply module.

• DSD calculates the entire power requirement. For operation in generator mode it is checked

whether the braking power needs to be dissipated via an additional brake resistor.

 Regenerative power supply module

M

3

P

mot

P

gen

P

mot

P

gen

i

1

i

1,1

P (t)

1

M

P

mot

P

gen

i

2

i

2,1

P (t)

2

M

P

mot

P

gen

i

n

i

n,1

P (t)

n

DC

2

-

3

~

-

3

~

-

3

~

-

3

~

0

R

B

3 AC

DC bus

M

3~

2

2

3

3

M

3~

...

...

2

3

3

=

~

=

~

=

~

=

~

=

~

Advertising