3 intermittent operation s3, s4, s5, Intermittent operation s3, s4, s5, 8motion design – Lenze DSD User Manual

Page 272

Advertising
background image

8

Motion design

8.3

Predefined motion profile according to operating mode

272

Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.3.3

Intermittent operation S3, S4, S5

The intermittent operation consists of a sequence of identical cycles, each of which including an op-

erating time with constant load and a downtime.
Starting and braking times as well as inertias are characteristics of the respective operating mode:

• S3: The starting current is irrelevant for the motor heating.
• S4: The starting process is thermally relevant in addition.
• S5: The brake reaction is additionally relevant.

[8-11] Motion profile for operating mode S3

t

BRK = 1

CINH = 1

t

acc

t

dec

Description
t

Cycle time, corresponds to the duration of the load phase.

t

acc

Acceleration time required by the drive until the constant load condition is reached.

t

dec

Deceleration time required by the drive until standstill.

BRK

Brake, BRK = 1: brake active

CINH Controller inhibit, CINH = 1: controller inhibit active