4 max. permissible resistance value is exceeded, 6 temperature monitoring of the cartridge responds, 18 drive dimensioning messages – Lenze DSD User Manual

Page 482

Advertising
background image

18

Drive dimensioning messages

18.12

Brake resistor

482

Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

18.12.4

Max. permissible resistance value is exceeded

18.12.5

Thermal time constant of the brake resistor is too small

18.12.6

Temperature monitoring of the cartridge responds

Note!

The resulting brake resistance is > 220 Ohms.

The inverter may shut off due to overvoltage.

Select resistance value between 180 and 220 Ohms.

Cause

Effects

Possible remedies

The max. permissible resistance has

been exceeded.

Due to overvoltage, the inverter

switches off.

• The drive will not be braked to

standstill at the deceleration

ramp anymore.

Select brake resistor with a resist-

ance between 180 and 220 Ohm.

Warning!

The brake resistor has a thermal time constant <120 s.

In case of an uncoordinated DC-bus connection, the time constant must be >120 s.

DSD cannot carry out a safe check of the brake resistor.

Cause

Effects

Possible remedies

With an uncoordinated multi-axis

system, only brake resistors with

thermal time constant >120 s are

permissible.

The brake resistor is overheated.

Fire hazard!

Select a brake resistor with a higher

thermal time constant.

Warning!

Temperature monitoring of the brake cartridge responds.

Do not use brake cartridge! Device may be destroyed!

Cause

Effects

Possible remedies

For the brake cartridge used, an addi-

tional temperature monitoring mode

is calculated in the device. This tem-

perature monitoring responds.

The device may be destroyed.

• Use of the brake cartridge is not

permissible.

• Use external brake resistor.

Advertising