2 max. ambient temperature, inverter, Max. ambient temperature, inverter, 9mains and environment – Lenze DSD User Manual

Page 279

Advertising
background image

Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23

279

9

Mains and environment

9.2

Ambient conditions

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

For motors without a gearbox the following correction values k

ϑ

result:

9.2.2

Max. ambient temperature, inverter

DSD considers the drive-specific reduction factors and an ambient temperature range of 0 ... 60 °C.

• The ranges from -20 ... 0 °C have to be checked manually.
• In a temperature range of 0 ... 40 °C, operation of the components can be carried out without a

power derating.

• For inverters the derating factor is stored in the DSD device-specifically.

ϑ

opr

k

ϑ

0 ... 40 °C

1

≤ 45 °C

0.95

≤ 50 °C

0.9

≤ 55 °C

0.85

≤ 60 °C

0.8

Note!

• The DSD does not take sub-zero temperatures into consideration.
• For an ambient temperature < 0 °C you enter 0 °C.
• Make sure that the ambient conditions suit the motors. As a help, use the tables with

the correction values.

Note!

The upper and lower limit values can vary for the different inverters.
In the chapter "

Inverters

"

( 346)

the characteristics of the different inverter types are

listed.