10.3.4

Inverter properties

In the subchapters, the inverters available in DSD are described. The tabular representation makes

it possible for you to easily compare the properties to each other.

10.3.4.1

Frequency inverter

Frequency inverters are suitable for simple, speed-controlled drive tasks, and they are cost-effective.

A speed feedback is not necessarily required.

8400 BaseLine

8400 StateLine

8400 HighLine

Illustration

Short description

Frequency inverters with integrated

keypad, V/f control and sensorless

vector control, overload capacity up

to 180 %, pluggable memory chip for

the parameter set

Scalable frequency inverter, V/f con-

trol with feedback, sensorless vector

control, overload capacity up to

200 %, optionally with integrated

safety functions, fieldbus communi-

cation, pluggable memory chip for

the parameter set

Scalable frequency inverter, V/f con-

trol with feedback, sensorless vector

control, point-to-point positioning,

free function block interconnection,

optionally with integrated safety

functions, fieldbus communication,

pluggable memory chip for the pa-

rameter set

Voltage range/power range

1 AC 180 … 264 V: 0.25 … 2.2 kW

3 AC 320 … 550 V: 0.37 … 3.0 kW

1 AC 180 … 264 V: 0.25 … 2.2 kW

3 AC 320 … 550 V: 0.37 … 45 kW

1 AC 180 … 264 V: 0.25 … 2.2 kW

3 AC 320 … 550 V: 0.37 … 45 kW

Approvals

CE, UL, GOST-R, RoHS

CE, UL, GOST-R, RoHS

CE, UL, GOST-R, RoHS

Permissible power systems

TN, TT,

RoHS-compliant

TN, TT, IT,

RoHS-compliant

TN, TT, IT,

RoHS-compliant

Switching frequencies

2, 4, 8, 16 kHz

2, 4, 8, 16 kHz

2, 4, 8, 16 kHz

Mechanical design

Built-in unit

Push-through technique

 (up to 15 kW)

 (up to 15 kW)

Cold plate technique

 (up to 22 kW)

 (up to 22 kW)

Enclosure

IP 20

IP 20

IP 20

Operation in generator mode

Integrated brake resistor

 (3 AC 400/500 V)

External brake transistor

 (1 AC 230/240 V)

Regenerative

Control types

V/f control

Vector control (encoderless)

V/f control

VFC eco

Synchronous motors (encoderless)

Servo control

Drive function

Voltage / frequency control

Torque control

Closed-loop speed control

-

PID controller

Motion Control