2 s2, short-term operation, S2, short-term operation, 8motion design – Lenze DSD User Manual

Page 271

Advertising
background image

Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23

271

8

Motion design

8.3

Predefined motion profile according to operating mode

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.3.2

S2, short-term operation

The operating time with constant load does not suffice to reach the thermal steady state. During

the break that follows, the motor can cool down to the initial temperature.

[8-10] Motion profile for operating mode S2

t

BRK = 1

CINH = 1

t

acc

t

dec

Description
t

Cycle time, corresponds to the duration of the load phase.

t

acc

Acceleration time required by the drive until the constant load condition is reached.

t

dec

Deceleration time required by the drive until standstill.

BRK

Brake, BRK = 1: brake active

CINH Controller inhibit, CINH = 1: controller inhibit active

Advertising