7.21

Dimension the multi-axis system

186

Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Parallel connection of several regenerative power supply modules

[7-183] Parallel connection of several regenerative power supply modules

• When the derating factors are complied with, the operation of several regenerative power sup-

ply modules in the DC-bus connection is permitted.

• The arrangement in the DSD can only be dimensioned with regenerative power supply modules

9400.

• The regenerative power supply modules can be each dimensioned separately in the DSD.
• The selection table in the DSD provides regenerative power supply modules 9400 connected

in parallel (2 × E94... or 3 × E94...).

Single-axis application
For applications with a high regenerative power (e. g. unwinders and hoists) it may also be reason-

able to use a regenerative power supply module for a drive axis.

[7-184] One drive axis with supply/feedback

3 AC

DC bus

2

3

3

2

3

3

=

~

=

~

M

3~

2

M

3~

...

...

2

3

3

=

~

=

~

=

~

=

~

 Regenerative power supply module