Description

Indirect tension control via the

drive torque with disturbance com-

pensation (friction, acceleration).

Closed-loop torque-controlled

mode with a higher-level trac-

tion control loop and distur-

bance compensation (friction,

acceleration). Actual value of

tensile force is detected via sen-

sor in web.

Closed-loop speed-controlled

mode with a higher-level traction

control loop and disturbance

compensation (friction, accelera-

tion). Actual value of tensile force

is detected via sensor in web.

Tension control via dancer. Speed-control-

led and position-controlled operation of

the drive. Further tasks of the dancer: de-

tection of the actual position. Web accu-

mulator for the compensation of

eccentricities of the reel (e.g. in the case of

unwinders) and discontinuities.

The tensile force is determined by the

upstream system. The winder acts as

master in the drive system and conveys

material at a constant circumferential

speed. Closed-loop control of the cir-

cumferential speed and speed.

Application area

Universal, cost-effective winding

procedure for low to high require-

ments with regard to tensile force

quality and tensile force profile.

Winding procedure for high re-

quirements with regard to ten-

sile force quality and tensile

force profile.

Winding procedure for high re-

quirements with regard to tensile

force quality and tensile force

profile.

Universal, cost-effective winding proce-

dure for low to high requirements with re-

gard to tensile force quality and tensile

force profile. Well suited for eccentric

reels, e.g. in the case of unwinders.

Unwinders for slitting lines.

Control system
SC

Rewinder/unwinder

+

+

+

+

+

VFCplus without encoder

Rewinder/unwinder

0

0

SLVC

Rewinder

+

0

+

Unwinder

VFCplus with encoder

Rewinder

0

0

0

Unwinder

0

0

VFCplus eco

Rewinder/unwinder

+ Well-suited

SC Servo control

0 Suitable with restrictions

VFCplus V/f control

– Not suitable

VFCplus eco V/f control with energetically optimised field injection in the partial load operational range

1)

Comparison of tension-controlled winder control modes

( 214)

SLVC Sensorless

vector

control

Tension control (M)

Tension control (M)

1)

Tension control (n)

1)

Dancer position control (n)

Velocity control (n)

Advertising