5 lenze motor, Utilisation >100 %, regarding the effective torque, 18 drive dimensioning messages – Lenze DSD User Manual

Page 455

Advertising
background image

Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23

455

18

Drive dimensioning messages

18.5

Lenze motor

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

18.5

Lenze motor

18.5.1

Utilisation >100 %, regarding the effective torque

18.5.2

Max. motor speed is higher than the permissible motor speed

18.5.3

Max. motor torque is higher than the permissible motor torque

Warning!

The utilisation of the motor relative to the effective torque is xxx %. Thus the limit value of 100 % is ex-

ceeded.

Cause

Effects

Possible remedies

The calculated effective torque of the

application on the motor is higher

than the permissible torque.

The motor is thermally overloaded.

• Select different motor.

• Select a higher ratio if the speed

range of the motor is badly uti-

lised.

Warning!

The max. occurring motor speed is xxx rpm. Thus the max. permissible motor speed of yyy rpm is exceed-

ed.

Cause

Effects

Possible remedies

The maximum speed that occurs is

higher than the maximum permissi-

ble speed of the motor.

The motor is mechanically destroyed!

• Reduce gearbox ratio or speed.

• Select motor with a higher per-

missible speed.

Warning!

The maximum permitted torque of the motor is exceeded. The motor might get damaged!

Cause

Effects

Possible remedies

For servo motors, the maximum per-

missible torque may not be exceed-

ed. This limit is compared to the

occurring max. torque (absolute val-

ue).

The motor is mechanically/electrical-

ly overloaded.

• Select bigger motor.

• If required, reduce load.

• If the use of a gearbox is intend-

ed, the torque can be reduced

by a greater ratio.

Advertising