Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23

189

7

Applications

7.21

Dimension the multi-axis system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.21.2.3

Central mains supply via inverter

[7-189] Central mains supply via inverter

• The arrangement cannot be dimensioned in the DSD.

• The drive axes can be each dimensioned separately in the DSD.
• The DC parameters for the inverter on the mains must be calculated manually. The required

intermediate results are provided by DSD.

• The entire power balance must be calculated manually.

• The operation of i700 axis modules via the DC bus of an inverter is principally possible.

• The drive axes can be each dimensioned separately in the DSD.
• The DC parameters for the inverter on the mains must be calculated manually. The required

intermediate results are provided by DSD.

7.21.2.4

Decentralised mains supply via several inverters

[7-190] Decentralised mains supply via several inverters

• The arrangement cannot be dimensioned in the DSD.

• The drive axes can be each dimensioned separately in the DSD.
• Additional parameters for the DC bus connection must be determined manually.