Mains and environment

9.2

Ambient conditions

280

Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

9.2.3

Site altitude

The components can be operated up to a site altitude of 1000 m amsl without power reduction.

• From 1000 ... 4000 m amsl there is a power reduction.
• For inverters the derating factor is stored in the DSD device-specifically.
• The site altitude for geared motors is considered as a function of the temperature:

• For motors without a gearbox, the following applies:

ϑ

opr

k

h

1000 m

2000 m

3000 m

4000 m

20 °C

1.15

1.04

0.92

0.81

30 °C

1

0.9

0.8

0.70

40 °C

0.8

0.72

0.64

0.56

50 °C

0.6

0.54

0.48

0.42

60 °C

0.4

0.36

0.32

0.28

h

k

h

0 ... 1000 m

1

≤ 2000 m

0.95

≤ 3000 m

0.9

≤ 4000 m

0.85

Advertising