4 dimensioning, 7applications – Lenze DSD User Manual

Page 192

Advertising
background image

7

Applications

7.21

Dimension the multi-axis system

192

Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.21.4

Dimensioning

[7-192] General procedure of dimensioning a coordinated multi-axis system

Describe kinematics for the

drive axes

Dimension the drive axis

Enter the

application data

Dimension the

components

Load the motion

profile

Dimension the

drive axis?

Dimension the multi-axis

system

Read in the drive

axes (*.dsd)

DSD project

Drive axis

(*.dsd)

Dimension the

components

No

Yes

DSD project

Multi-axis system

(*.dsd)

Motion profile

(*.lmp)

1

2

3

Description

Go to the independent MotionDesigner, create the motion profiles for all drive axes and save them to a file

(*lmp).

Movement of drive axes ( 195)

Dimension all drive axes of the multi-axis system.

• Load the Imp file with the motion profiles in the MotionDesigner of the drive axis, select and accept the

corresponding motion profile.

• Select "Inverter with DC supply (multi-axis application)" as electrical drive concept. DSD automatically re-

duces the selection and only offers inverters that are suitable for the DC-bus connection.

• Dimension components and consider the compatibility of the products in the DC bus.

Combining Lenze products ( 191)

• The power in generator and motor mode in the DC bus is calculated separately. DSD considers influenc-

ing values as power required of the application, power loss of the drive components and kinetic energy

demand due to mass inertia.

Select the "Dimension multi-axis system" application and read in the DSD projects of the drive axes.

• Optional processing for each DSD project:

• Time displacement of the motion profile.

• Multiple repetition of the motion profile.

• Number of drive axes for a DSD project.

• Dimension components and define possible supply strategies:

Central mains supply via regenerative power supply module ( 185)

Central mains supply via power supply module ( 187)

Advertising