10 supply module, 1 ambient temperature too low, 2 ambient temperature too high – Lenze DSD User Manual

Page 476: 3 max. site altitude exceeded, 18 drive dimensioning messages

Advertising
background image

18

Drive dimensioning messages

18.10

Supply module

476

Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

18.10

Supply module

18.10.1

Ambient temperature too low

18.10.2

Ambient temperature too high

18.10.3

Max. site altitude exceeded

18.10.4

Utilisation exceeded, regarding the max power (supply)

Note!

The ambient temperature of the inverter is xxx °C. Thus the value falls below the required minimum am-

bient temperature of the power supply module of yyy °C.

Cause

Effects

Possible remedies

The ambient temperature is too low. The component can be damaged.

Select air-conditioned control cabi-

net.

Warning!

The ambient temperature of the inverter is xxx °C. Thus the max. permissible ambient temperature of the

power supply module of yyy °C is exceeded.

Cause

Effects

Possible remedies

The ambient temperature is too high. The power supply module switches

itself off due to a too high tempera-

ture.

• Select a different power supply

module.

• Select air-conditioned control

cabinet.

Warning!

The site altitude is xxx m. It thus falls below the max. permissible site altitude of the power supply module

of xxx m.

Cause

Effects

Possible remedies

Due to the lower atmospheric pres-

sure, the cooling effect of the air is re-

duced.

The power supply module is not

cooled sufficiently.

Contact Lenze

Warning!

The max. permissible power of the power supply module in supply mode is exceeded.

The utilisation is xxx %.

Cause

Effects

Possible remedies

The max. power in the DC bus is too

high for the device.

The drive is overloaded.

Select larger drive.