11

Drive Dimensioning

11.2

Motor selection

320

Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Description of the parameters

Parameter

Unit

Description

Metric

Imperial

k

f

Field weakening factor

• With the slider you can adapt the max. speed in ad-

vance.

A

rated

~(n

max

)

Previously calculated utilisation of the motor

• The utilisation is calculated from the ratio of the max.

motor speed to its rated speed.

Possible messages:

Utilisation >100 %, regarding the max. torque ( 445)

A~(M

max

)

Utilisation of the motor calculated in advance with refer-

ence to the max. torque in the M-n characteristic.

A

th

,

M

~

(M

rms

)

%

%

Thermal utilisation of the motor with regard to the effec-

tive torque
Relevant topics:

Continuous rated curves (S1 characteristics) ( 317)

Possible messages:

Utilisation >100 %, regarding the effective torque

( 455)

Type

Type code (excerpt)

• Specification of the motor type.

P

rated

kW

kW

Rated power of the motor

M

rated

Nm

lbfft

Rated torque of the motor

f

rated

Hz

Hz

Rated frequency

I

rated

A

A

Rated current

n

rated

rpm

rpm

Rated speed

P

th,av,M

kW

kW

Medium power loss of the motor

I

max

~

A

A

Previously determined max. required application current

k

J

~

Previously calculated load matching

• Mismatch of the moment of inertia

Relevant topics:

Load-matching factor ( 321)

Possible message:

Max. mismatch is higher than permissible mismatch

( 456)

cos ϕ

Power factor

IP

Protection type of the motor

Cooling

Type of motor cooling

S Naturally ventilated (surface-ventilated)
E Self-ventilated (integral fan)

F Forced ventilated

V

rated

V

V

Rated voltage

Y/Δ

Connection method

S Y-connection

D Δconnection

Advertising