18

Drive dimensioning messages

18.8

Inverters

470

Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

18.8.17

SLVC and VFCplus control modes not possible for synchronous motors

18.8.18

No product options available

18.8.19

Mains choke required

18.8.20

Special measures for operation with increased rated power

Warning!

The SLVC and VFCplus control types are not possible for the synchronous motor.

Select other control modes.

Cause

Effects

Possible remedies

The control modes vector control

(SLVC) and V/f control (VFCplus) are

not intended for this operating

mode.

Motor control is not possible.

Select other control modes.

Note!

No product options are available for the selected inverter.

Configure product options manually.

Cause

Effects

Possible remedies

No product options are available in

the DSD.

Product options cannot be selected. Configure product options manually:

• »Drive Solution Catalogue« (DSC)

• Product catalogue

• SAP

Note!

A mains choke is required for the inverter.

Cause

Effects

Possible remedies

The inverter must be operated via a

mains choke for the selected operat-

ing mode.

Rectifier in the inverter is overloaded. Use mains choke.

Note!

For the inverter, an operation with increased rated power has been selected.

Special measures are required. Observe information in the hardware manual.

Cause

Effects

Possible remedies

For operation with increased rated

power, losses in the inverter must be

limited. For this purpose, some meas-

ures must be taken, especially with

regard to the changed switching fre-

quency.

• Inverter gets too hot.

• Rectifier in the inverter is over-

loaded.

Implement required measures ac-

cording to hardware manual:

• Installation type

• Assigned fuses and cable cross-

sections

• Mains chokes and filters

• Parameter setting of the inverter