3 "motor" image, 4 "inverter" image, 3user interface – Lenze DSD User Manual

Page 30

Advertising
background image

3

User interface

3.1

Control and function elements

30

Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.1.3.3

"Motor" image

3.1.3.4

"Inverter" image

Symbol

Description

P

N

Rated power of the motor

n

rated

Rated speed of the motor

M

rated

Rated torque of the motor

I

N

Rated motor current

A

th,max

Max. thermal utilisation of the motor

A(M

max

)

Utilisation of the motor relative to the torque

• Ratio of the max. required torque to the max. possible torque of the motor during operation

on the selected inverter and with the selected control mode:

M

max,req

/ M

max,M

A(M

rms

)

Utilisation of the motor with reference to the effective torque and taking into account the ther-

mal time constant

A(M

dyn,M

)

Dynamic utilisation of the motor

• Ratio of the max. occurring motor torque to the rated motor torque:

(M

max

/ M

N

)

k

f

Field weakening factor of the motor

k

J,max

Load-matching factor of the motor

Symbol

Description

A(I

max

/ I

rated,M

)

Utilisation of the inverter

• Ratio of the max. output current of the inverter (I

max

) to the rated motor current (I

N,M

).

• If the inverter is highly overdimensioned with regard to the motor, the control quality de-

creases.

A(I

imp,max

)

Thermal utilisation of the inverter relative to the power pulse current for 1 s or 60 s

A(I

red,max

)

Utilisation of the inverter relative to the reduced max. output current

A

th,Brm

Thermal utilisation of the internal brake transistor

A

Brm

(ED)

Utilisation of the internal brake transistor, relative to the i×t monitoring

A

max

Max. utilisation of the brake resistor

A

th

Thermal utilisation of the brake resistor

A

th,max

Max. thermal utilisation of the inverter relative to the reduced output current

I

max

Max. output current of the inverter selected

I

N

Rated current of the inverter selected

P

N

Rated motor power of the inverter selected

Type

Type of brake resistor

Advertising