_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

• The table below provides guide values for minimum acceleration and deceleration times. If the

values fall below these values, the behaviour of the control system of the drive must be checked

in addition.

VFCPlus

SLVC

SC

t

acc,set

/t

dec,set

t

acc,set

/t

dec,set

t

acc,set

/t

dec,set

Servo inverters
i700

< 100 ms

< 50 ms

Servo Drives 9400
Inverter Drives 8400 TopLine
Frequency inverter
Inverter Drives 8400 BaseLine

< 100 ms

< 500 ms

< 50 ms

Inverter Drives 8400 StateLine
Inverter Drives 8400 HighLine
Inverter Drives 8400 TopLine
Decentralised inverters
Inverter Drives 8400 motec

< 100 ms

< 500 ms

Inverter Drives 8400 protec

< 100 ms

< 500 ms

< 50 ms

The following conditions must be complied with:

• t

r,set

> t

dyn,min

• t

f,set

> t

dyn,min

VFCPlus

Voltage frequency control

SLVC

Sensorless vector control

SC

Servo control

t

acc,set

Acceleration time - setpoint

t

acc,act

Acceleration time - actual value

t

dec,set

Deceleration time - setpoint

t

dec,act

Deceleration time - actual value

t

dyn,min

Dynamic acceleration and deceleration time that the control system of the inverter is able to realise at

least

Note!

Without a specific feedforward control of the required acceleration torque within the in-

verter, these control-related delay times are to be taken into consideration.
If the actual times are lower than the delay times, a control-related system consideration

on the basis of empirical checks (e. g. on a test configuration) or by an appropriate simu-

lation has to be carried out in addition to the drive dimensioning with the DSD.