17

Restrictions of the drive dimensioning

17.20

Applications with low field frequencies

438

Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

17.20

Applications with low field frequencies

Low output frequencies are to be expected in particular if the motor is loaded at standstill or at very

low speeds (f

d

< 1 Hz).

• During longer operation in this range, inverter and motor may be thermally overloaded.

17.21

Emergency-off scenarios

For specific applications, information is required on how fast the drive can be stopped in emergency

situations under defined conditions.

• This calculation currently is not yet integrated in the DSD.

Tip!
Emergency stop scenarios can be calculated with the Application Tuner by changing the

motion profile with the emergency stop times. That way, you can check whether the drive

will still be able to handle the emergency stop scenarios.

Application Tuner

( 59)

17.22

Switching in the motor cable

This check has to be carried out manually:
If several motors are operated parallel at the output of an inverter (group drives), and if they are

switched via contactor while a current is applied, further checks have to be carried out.

17.23

Filter in the motor cable

Reasons for the use of filters in the motor cable:

• An increase of the maximally permissible cable length.
• Avoiding the use of shielded motor cables.
• Protection of the motor winding against too high speeds for voltage rises.

The filters have to be dimensioned manually or by means of the DSC.

Note!

Relevant for all inverters, in particular for frequency inverters!

Note!

Only relevant for frequency inverters, for servo inverters the use of filters is not permis-

sible!