14 brake at standstill, 15 controller inhibit at standstill, 7applications – Lenze DSD User Manual

Page 223

Advertising
background image

Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23

223

7

Applications

7.22

Winding drive for rewinder/unwinder

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.22.7.14 Brake at standstill

7.22.7.15 Controller inhibit at standstill

7.22.7.16 Emergency-off time (without material, M-calculation only)

Parameter

Description

Active

Yes: The brake is active during downtimes 1 ... 3. If the brake is activated, the motor does not

have to provide a torque.

No: The brake is not active during downtimes 1 ... 3.

Parameter

Description

Active

Yes: The controller of the inverter is inhibited during downtimes 1 ... 3. The thermal load of

the inverter and the motor is reduced.

No: The controller of the inverter is enabled during downtimes 1 ... 2.

• The controller is always inhibited during downtime 3.

Parameter

Description

t

ES

Deceleration time until the drive is at standstill, e.g. if the web breaks.

• Only the required motor torque is calculated.

• The dimensioning must be checked manually.