17

Restrictions of the drive dimensioning

17.17

Parallel operation of several motors on one inverter (group drives)

436

Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

17.17

Parallel operation of several motors on one inverter (group drives)

Such a dimensioning at present is not yet supported by the DSD.

[17-6] Group drives

Remedy
When entering the data in the DSD, divide the masses, moments of inertia, and tensile forces or

counterforces by the number of motors involved in the application (applies to the motor and gear-

box selection). The inverter in this case has to be selected manually, since it has to operate the sum

of the motors.

Note!

Relevant only for specific applications, e. g. hoists, winders, caterpullar take-offs, pumps

and power conveyors.