4 intermittent load s6, s7, Intermittent load s6, s7, 8motion design – Lenze DSD User Manual

Page 273

Advertising
background image

Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23

273

8

Motion design

8.3

Predefined motion profile according to operating mode

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.3.4

Intermittent load S6, S7

Operation composed of a sequence of identical cycles each of which including an operating time

with constant load and an idle time. There is no idle time.

[8-12] Motion profile for operating mode S6

ED

t

t

t

acc

t

dec

Description
t

Cycle time, corresponds to the duration of the load phase.

t

acc

Acceleration time required by the drive until the constant load condition is reached.

t

dec

Deceleration time required by the drive until standstill.

OT

Relative operating time

• Percentage ratio of duration of load phase to duration of no-load phase.

Advertising