473

18

Drive dimensioning messages

18.9

Regenerative power supply module

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

18.9

Regenerative power supply module

18.9.1

Ambient temperature too low

18.9.2

Ambient temperature too high

18.9.3

Max. site altitude exceeded

18.9.4

Utilisation (supply) relative to the max. DC-bus current > 100 %

Note!

The ambient temperature of the inverter is xxx °C. Thus the value falls below the required minimum am-

bient temperature of the regenerative power supply module of yyy °C.

Cause

Effects

Possible remedies

The ambient temperature is too low. The component can be damaged.

Select air-conditioned control cabi-

net.

Warning!

The ambient temperature of the inverter is xxx °C. Thus the max. permissible ambient temperature of the

regenerative power supply module of yyy °C is exceeded.

Cause

Effects

Possible remedies

The ambient temperature is too high. The regenerative power supply mod-

ule switches itself off due to a too

high temperature.

• Select a different regenerative

power supply module.

• Select air-conditioned control

cabinet.

Warning!

The site altitude is xxx m. It thus falls below the max. permissible site altitude of the regenerative power

supply module of yyy m.

Cause

Effects

Possible remedies

Due to the lower atmospheric pres-

sure, the cooling effect of the air is re-

duced.

The regenerative power supply mod-

ule is not cooled sufficiently.

Contact Lenze

Warning!

The utilisation of the regenerative power supply module relative to the max. DC-bus current for supply is

xxx %. Thus the limit value of 100 % is exceeded.

Cause

Effects

Possible remedies

The max. DC-bus current is higher

than the permissible DC-bus current

The drive is overloaded.

Select larger drive.