Applications

7.20

Importing M-n-operating points

182

Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.20.1

Data for the entry

Symbol

Description

Dimension unit

n

Speed of application

rpm, rad/s, °/s

M

Torque of the application, including components due to moment of inertia Nm, kNm, ozfin,

lbfin, lbfft

J

Moment of inertia

• Only required if k

j

must be calculated.

• Required for the calculation of the torque.

kgm², kgcm²,

ozin², lbin², lbft²,

ozins², lbins²

t

Time

s, ms, min, h

BRK

Control signal for the holding brake (BRK)

-

CINH

Control signal for controller inhibit of the inverter (CINH)

-

Note!

• The units of the data to be imported have to correspond to the units to be set in the

input mask.

• The DSD can import ASCII files with approx. 300 operating points without problems.

The greater the number of interpolation points, the longer the import takes.

• The data for the motion profile can be easily entered in Microsoft® Excel and then be

saved as an ASCII file.