7.22

Winding drive for rewinder/unwinder

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.22.5

Checking emergency-off scenarios

DSD is only partially able to check emergency-off scenarios. The user interface and the DSD protocol

display a note.

[7-234] Motor diagram: winder torque (diameter-related)

The Application Tuner may help with the required additional checks.

Application Tuner

( 59)

Note!

The torque required for emergency stop is greater than the drive torque available.

• The torque required for emergency stop is calculated and represented in the diame-

ter-dependent torque diagram of the motor. The calculation is based on the emergen-

cy stop time, a linear motion profile, and a tensile force = 0 N (material crack).

• The thermal utilisation of the drive components is not checked.
• Braking circuits are not dimensioned.

Description

Torque required for emergency stop

Max. available drive torque