Rockwell Automation Publication 1426-UM001F-EN-P - November 2013

229

PowerMonitor 5000 Unit Data Tables

Appendix A

Bit 8

SetPoint19Active

1 Indicates the setpoint is Active

0 or 1

Bit 9

SetPoint20Active

1 Indicates the setpoint is Active

0 or 1

Bit 10 - 15

Reserved

Future Use

0

8

2

Int16

DiscreteOutputStatus

Discrete Output status

0 or 1

Bit 0

KYZLogicState

KYZ Logic State

0 or 1

Bit 1

R1LogicState

Relay 1 Logic State

0 or 1

Bit 2

R2LogicState

Relay 2 Logic State

0 or 1

Bit 3

R3LogicState

Relay 3 Logic State

0 or 1

Bit 4

KYZReadback

Indicates Output KYZ Energized

0 or 1

Bit 5

KYZForcedOn

Software Control Forced On KYZ

0 or 1

Bit 6

KYZForcedOff

Software Control Forced Off KYZ

0 or 1

Bit 7

R1Readback

Indicates Output Relay 1 Energized

0 or 1

Bit 8

R1ForcedOn

Software Control Forced On Relay 1

0 or 1

Bit 9

R1ForcedOff

Software Control Forced Off Relay 1

0 or 1

Bit 10

R2Readback

Indicates Output Relay 2 Energized

0 or 1

Bit 11

R2ForcedOn

Software Control Forced On Relay 2

0 or 1

Bit 12

R2ForcedOff

Software Control Forced Off Relay 2

0 or 1

Bit 13

R3Readback

Indicates Output Relay 3 Energized

0 or 1

Bit 14

R3ForcedOn

Software Control Forced On Relay 3

0 or 1

Bit 15

R3ForcedOff

Software Control Forced Off Relay 3

0 or 1

10

2

Int16

Year

The currrent year.

2010

2010…2100

12

2

Int16

Month

The current month.

1

1…12

14

2

Int16

Day

The current day.

1

1…31

16

2

Int16

Hour

The current hour.

0

0…23

18

2

Int16

Minute

The current minute of the day

0

0…59

20

2

Int16

Seconds

The current seconds

0

0…59

22

2

Int16

Millisceconds

The current milliseconds

0

0…99

24

2

Int16

PFLeadLag

L1 lead or lag indicator for power factor 1 = leading, -1 = lagging.

+/-

-1…1

26

2

Int16

DiscreteInputStatus

Discrete Input status

Bit 0

S1

Indicates Status 1 actuated

0 or 1

Bit 1

S2

Indicates Status 2 actuated

0 or 1

Bit 2

S3

Indicates Status 3 actuated

0 or 1

Bit 3

S4

Indicates Status 4 actuated

0 or 1

Bit4-Bit15

Reserved

Future Use

0

28

4

Real

V1ToVNVoltage

V1 to N true RMS voltage

V

0…9.999E15

32

4

Real

V2ToVNVoltage

V2 to N true RMS voltage

V

0…9.999E15

36

4

Real

V3ToVNVoltage

V3 to N true RMS voltage

V

0…9.999E15

40

4

Real

VNToVGVoltage

VN to G true RMS voltage

V

0…9.999E15

44

4

Real

AvgVtoVNVoltage

Average of V1, V2 and V3.

V

0…9.999E15

Table 40 - ScheduledData.Input Data Table

Start
Byte

Size Type

Tag

Name

Description

Units

Range