Rockwell Automation 1426 PowerMonitor 5000 Unit User Manual

Page 322

Advertising
background image

322

Rockwell Automation Publication 1426-UM001F-EN-P - November 2013

Appendix A

PowerMonitor 5000 Unit Data Tables

18

Int16

Level1 Gate4 Transitions to
Active x1

The number of actuations for setpoint times 1

x1

0…999

19

Int16

Level1 Gate4 Transitions to
Active x1000

The number of actuations for setpoint times 1000.

x1000

0…9999

20

Int16

Level1 Gate5 Seconds
Accumulator

Time accumulator counter for seconds part of total accumulated time.

Sec

0…999

21

Int16

Level1 Gate5 Minutes
Accumulator

Time accumulator counter for minutes part of total accumulated time.

Min

0…59

22

Int16

Level1 Gate5 Hours
Accumulator

Time accumulator counter for total hours of accumulated time.

Hr

0…9999

23

Int16

Level1 Gate5 Transitions to
Active x1

The number of actuations for setpoint times 1

x1

0…999

24

Int16

Level1 Gate5 Transitions to
Active x1000

The number of actuations for setpoint times 1000.

x1000

0…9999

25

Int16

Level1 Gate6 Seconds
Accumulator

Time accumulator counter for seconds part of total accumulated time.

Sec

0…999

26

Int16

Level1 Gate6 Minutes
Accumulator

Time accumulator counter for minutes part of total accumulated time.

Min

0…59

27

Int16

Level1 Gate6 Hours
Accumulator

Time accumulator counter for total hours of accumulated time.

Hr

0…9999

28

Int16

Level1 Gate6 Transitions to
Active x1

The number of actuations for setpoint times 1

x1

0…999

29

Int16

Level1 Gate6 Transitions to
Active x1000

The number of actuations for setpoint times 1000.

x1000

0…9999

30

Int16

Level1 Gate7 Seconds
Accumulator

Time accumulator counter for seconds part of total accumulated time.

Sec

0…999

31

Int16

Level1 Gate7 Minutes
Accumulator

Time accumulator counter for minutes part of total accumulated time.

Min

0…59

32

Int16

Level1 Gate7 Hours
Accumulator

Time accumulator counter for total hours of accumulated time.

Hr

0…9999

33

Int16

Level1 Gate7 Transitions to
Active x1

The number of actuations for setpoint times 1

x1

0…999

34

Int16

Level1 Gate7 Transitions to
Active x1000

The number of actuations for setpoint times 1000.

x1000

0…9999

35

Int16

Level1 Gate8 Seconds
Accumulator

Time accumulator counter for seconds part of total accumulated time.

Sec

0…999

36

Int16

Level1 Gate8 Minutes
Accumulator

Time accumulator counter for minutes part of total accumulated time.

Min

0…59

37

Int16

Level1 Gate8 Hours
Accumulator

Time accumulator counter for total hours of accumulated time.

Hr

0…9999

38

Int16

Level1 Gate8 Transitions to
Active x1

The number of actuations for setpoint times 1

x1

0…999

39

Int16

Level1 Gate8 Transitions to
Active x1000

The number of actuations for setpoint times 1000.

x1000

0…9999

40

Int16

Level1 Gate9 Seconds
Accumulator

Time accumulator counter for seconds part of total accumulated time.

Sec

0…999

41

Int16

Level1 Gate9 Minutes
Accumulator

Time accumulator counter for minutes part of total accumulated time.

Min

0…59

42

Int16

Level1 Gate9 Hours
Accumulator

Time accumulator counter for total hours of accumulated time.

Hr

0…9999

Table 128 - Statistics.Setpoint_Logic Data Table

Element
Number

Type

Tag Name

Description

Units

Range

Advertising