ATEIS UAPg2 User Manual

Page 184

Advertising
background image

UAPG2 MANUAL

Version EN.24


184

The display/editor window displays an output to input graph, where the vertical axis corresponds to
the output signal level in dB, while the horizontal axis displays the input signal level in dB. The green
line reflects the currently set dynamic response graph of the compressor.

The small squares act as handles that can be dragged to the desired position and show the following
parameters:

o

red

Ratio x:1

o

blue

Threshold (dB)

o

yellow

Threshold range (dB)

Hard Clipping mode :

This is an example of a sinusoidal signal limited with and without Hard Clipping.

Without Hard Clipping

with Hard Clipping

Limiter Parameters

Parameter

Range

Comment

Graph...

Button

Opens the graphical display/editor window.

Threshold (dB)

60.0 to

20.0 dB

Sets the threshold level above which limiting begins.

Release time (ms)

10 to 1000 ms

Sets the time it takes to release gain reduction.

Bypass

On/Off

Bypasses the limiter's function.

Hard Clipping

On/Off

Enables/disables the “Hard clipping” mode.

Limiting

LED, lit red

Indicates limiting.

Gain reduction (dB)

0.0 to

-45.0 dB

Reflects the current amount of gain reduction.

Advertising