Version EN.24


92

6) When the adjustments are OK. Click to

(save) in order to store your adjustments in the

current Sub Preset (you make a kind of photocopy of the adjustments you have selected in this Sub
preset).

Repeat those actions with the other Sub preset.

7) If you want to load saved Sub Preset select the Sub Preset you want and click

(load).

Use a PPM

Because every remote device needs power, you will have to add external power supply every three
remotes devices or every 300 meters. Except for the first three remote devices or the first 300m,
power will be delivered by the UAPG2. The maximum distance between UAPG2 and remote device is
800m.

There are four main steps to configure a (or several) PPM(s):
1) Connect the PPM
2) Define the system with the PPM
3) Search and set the PPM (The UAPG2 scans the system and attributes a specific IP address for each

remote device (PPM and URC) automatically)

4) Adjust PPM's parameters

You can also assign chime to a PPM.

Note: Always clear remote address before installing or changing system with new PPMs. If during
the search process the system do not find the correct number of remote devices clear remote IP
then search again. If it doesn't correct the problem please check the wiring (to be sure that data A
and B are well connected: A to A and B to B).

Connect PPM

To connect PPM, use the RS485 connector. For several PPMs you may have to use Junction

boxes (JB). Connect Audio to the UAPG2 Input you want but take note of which PPM is connected to
which input (note the serial number).

After that, define the system with the PPM.

Note: If you have a bad connection: Switch on the end line resistor on the last Master PPM (rear of
PPM).
Slave feature is not available for the moment.