ATEIS UAPg2 User Manual

Page 220

Advertising
background image

UAPG2 MANUAL

Version EN.24


220

Parameter

Range

Comment

Ambiant noise

Meter

AGC Level

Meter

Display the current compensation gain

Hold time

1 to 5 sec

Holding time between when the P.M. signal passes below the mode

threshold and the end of the paging activity.

Paging activity

Light up when the paging is active.

(when P.M. is above the mode threshold)

Decrease Zone

Indicates that the AGC gain is decreasing

Dead Zone

Indicates that the AGC is not changing

Increase Zone

Indicates that the AGC gain is increasing

Fast Increase Zone

Indicates that the AGC gain is increasing fast

Sensing Mic Level

Indicator

/RMS

Show the input level of the sensing microphone

C/Sensing Mic Level

Indicator

Show the input level of the sensing microphone through the

calibration transfer function

Output Level

Indicator

/RMS

Show the output level

Differential Level

Indicator

Difference between the Output level and C/Sensing Mic level.


For the procedures and use, please see

Use the Automatic Gain Control

.


Advertising