UAPG2 MANUAL

Version EN.24

9

RS485 network). Wall mounted source selectors, smart controllers and programmable paging mikes
are available.

INSTALLATION

RACK MOUNTING:


If needed, fit the rack mounting brackets to each side of the UAPG2 by using the 6 pcs Phillips

M3X screws supplied with the package.

SITTING

The UAPG2 takes only a single 19’’ rack space and generates little heat itself. Consider leaving

enough ventilation space above and below the unit. Do not mount the UAPG2 directly above heat
generating devices like power supplies or power amplifiers.

UAPG2 cooling is provided by a fan at the left side of the unit. Be sure to not to block the air vent

holes along the sides of the housing. Normal operation is ensured within a temperature range
between 0°C and 40°C (32 °F to 104 °F).

POWER CONNECTION:

Connect the AC to the mains supply via a power cord. Check your line voltage before plugging in.

The power supply of the UAPG2 accepts AC voltages ranging from 100 V to 240 V, 50/60 Hz. The
UAPG2 can also be powered up from a 24 VDC supply; i. e. backup battery.