Parameter | Name:

C00615 | Resp. to imp. device config.

Data type: UNSIGNED_32

Index: 23960

d

= 5D98

h

Selection of response to impermissible device configuration
Selection list

1 Fault
3 Quick stop by trouble
4 Warning locked
6 Information
0 No response

Subcodes

Lenze setting

Information

C00615/1

0: No response

Reserved

C00615/2

1: Fault

Resp. to imperm. module in MXI1

C00615/3

1: Fault

Resp. to imperm. module in MXI2

C00615/4

0: No response

Reserved

C00615/5

0: No response

Reserved

;

Read access ; Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C00636 | Resp. to new module in MXI1

Data type: UNSIGNED_32

Index: 23939

d

= 5D83

h

Selection of the response to a new extension module being inserted into module slot MXI1.
Selection list

(Lenze setting printed in bold)

1 Fault
6 Information
5 Warning
4 Warning locked
3 Quick stop by trouble
0 No response

;

Read access ; Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C00637 | Resp. to new module in MXI2

Data type: UNSIGNED_32

Index: 23939

d

= 5D83

h

Selection of the response to a new extension module being inserted into module slot MXI2.
Selection list

(Lenze setting printed in bold)

1 Fault
6 Information
5 Warning
4 Warning locked
3 Quick stop by trouble
0 No response

;

Read access ; Write access … CINH … PLC STOP … No transfer

Scaling factor: 1