E94AYCCA communication manual (CANopen®)

Implemented CANopen objects

I-1014 - COB-ID EMCY

If a communication error or an internal error of the communication module or the

controller occurs or is acknowledged (e. g. "trouble"), an error message is sent via the

system bus (CANopen). For each error, the telegram is transmitted once. This function can

be activated or deactivated by means of bit 31.

 This object is related to the Lenze code

C13391

/

C14391

.

[14-7] Data telegram assignment

I-1015 - Inhibit time EMCY

Time which must elapse after an error message (

I-1014

) has been transmitted, before

further error messages can be sent via the system bus (CANopen).

 The entered value multiplied by "0.1" gives the delay time in [ms]. The values are

automatically rounded up to whole values in [ms].

 This object is related to the Lenze code

C13392

/

C14392

.

Index:

I-1014

Name:

COB-ID EMCY

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: COB-ID EMCY

0x80+Node-ID

0

4294967295 rw

U32

8th byte

7th byte

6th byte

5th byte

Data 4

Data 3

Data 2

Data 1

Bit 31

Bit 30

Bit 29 ... bit 11

Bit 10 ... bit 0

0/1

0

Extended identifier*

11-bit identifier

* The extended identifier is not supported - bit 11 ... bit 29 must be set to "0".

Bit

Setting

Bit 31

0 Emergency object valid.
1 Emergency object invalid.

Note!

The identifier can only be changed in the "Emergency object invalid" status (bit

31 = 1).

Index:

I-1015

Name:

Inhibit time EMCY

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: inhibit time EMCY

0

0

0.1 ms

65535 rw

U32