I-1801 - tpdo2 communication parameter, I-1801/1, E94aycca communication manual (canopen®) – Lenze E94AYCCA User Manual

Page 174: Implemented canopen objects

Advertising
background image

E94AYCCA communication manual (CANopen®)

Implemented CANopen objects

174

L

EDS94AYCCA EN 5.0 - 06/2012

Subindex 3 - inhibit time
The delay time can only be changed if the PDO is inactive (subindex 1, bit 31 = 1). The

entered value multiplied by 0.1 results in the delay time in [ms]. The calculated delay time

is always rounded down to an inter value.
Example:

 Value entered: 26
 Calculated time = 26 * 0.1 [ms] = 2.6 [ms]  delay time = 2 [ms}

I-1801 - TPDO2 communication parameter

Communication parameter for the transmission of process data via TPDO2

 For assignment of the data telegram see object

I-1800

.

Index:

I-1801

Name:

TPDO2 communication parameter

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: highest subindex supported

5

- (only read access)

ro

U8

1: COB-ID used by TPDO

0x280 + node ID

0

4294967295 rw

U32

2: transmission type

254

0

255 rw

U8

3: inhibit time

0 ms

0

0.1 ms

65535 rw

U16

4: reserved

-

- (reserved, write or read access results in error

message 0x06090011)

rw

U8

5: event timer

0 ms

0

ms

65535 rw

U16

Subindex

Meaning

Lenze code

1

Identifier TPDO2

• The basic setting is according to the "Predefined

Connection Set": Identifier = 0x280 + node ID

C13320/2

/

C14320/2

2

TPDO transmission type according to DS301, V4.02



Transmission type ( 47)

C13322/2

/

C14322/2

3

Minimum time between the transmission of two

identical TPDOs (see DS301, V4.02).

C13324/2

/

C14324/2

5

Cycle time with which the PDOs are transmitted with the

transmission type "254".

C13356/2

/

C14356/2