Page 160: Implemented canopen objects

Advertising
background image

E94AYCCA communication manual (CANopen®)

Implemented CANopen objects

160

L

EDS94AYCCA EN 5.0 - 06/2012

I-1011 - Restore default parameters

Load Lenze setting.

 Corresponds to the device command C00002 = "0: Load Lenze setting".
 This command serves to reset the parameters of the active application to the Lenze

setting which is stored in the firmware.

Read subindex 1

[14-5] Assignment of the data telegram (read )

Write subindex 1
In addition to the index and subindex, the telegram data must include the "load" signature

(ASCII characters; ISO 8859) so that the Lenze setting can be loaded.

 Writing with a wrong identifier causes a response according to the CANopen

specification DS301, V4.02.

[14-6] Assignment of the data telegram (write)

Index:

I-1011

Name:

Restore default parameters

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: highest subindex supported

1

- (only read access)

ro

U32

1: restore all default parameters

-

0

4294967295 rw

U32

Subindex

Meaning
Read

Write

0

Max. supported subindex: 1

-

(A write attempt triggers the error

message 0x06010002.)

1

Loading of all parameters possible.

Load Lenze setting.

8th byte

7th byte

6th byte

5th byte

Data 4

Data 3

Data 2

Data 1

Bit 31 ... bit 1

Bit 0

0

0/1

Bit

Setting

Bit 0

0 Parameters cannot be loaded.
1 Parameters can be loaded (Lenze).

8th byte

7th byte

6th byte

5th byte

Data 4

Data 3

Data 2

Data 1

"d" = 0x64

"a" = 0x61

"o" = 0x6F

"l" = 0x6C