2 electrical installation, 1 system bus (canopen) connection, Electrical installation – Lenze E94AYCCA User Manual

Page 26: System bus (canopen) connection, System bus (canopen) connection ( 26), E94aycca communication manual (canopen®), Installation electrical installation

Advertising
background image

E94AYCCA communication manual (CANopen®)

Installation

Electrical installation

26

L

EDS94AYCCA EN 5.0 - 06/2012

5.2

Electrical installation

5.2.1

System bus (CANopen) connection

 The system bus (CANopen) must be terminated with resistors (120 Ω) between CAN-

low and CAN-high.

 The Lenze system connector EWZ0046 with integrated terminating resistor complies

with the DS102-1 recommendation of the CAN user organisation CiA. The system

connector is not contained in the scope of supply of the communication module.

Documentation of the standard device, control system, and plant/machine
Observe the notes and wiring instructions stated.

E94YCCA002A

2181FEW004

L

EWZ0046

OF

F

ON

OFF

ON

ON

OFF

р

р

р

р

OUT

IN

IN

IN

On

Off

On

120

120

120

L

EWZ0046

L

EWZ0046

L

EWZ0046

Advertising