Technical data

General data and operating conditions

4

Technical data

4.1

General data and operating conditions

Field

Values

Order designation

E94AYCCA

Communication profile

CANopen (DS301, V4.02)

Communication medium

CAN cable according to ISO 11898-2

Network topology

Line terminated on both sides

(e.g. termination with Lenze system connector EWZ0046)

Adjustable node addresses

1 ... 127

Adjustable via DIP switches or code

C13350

/

C14350

.

Max. number of nodes

127

Baud rates [kbps]

• 10

• 20

• 50

• 125

• 250

• 500

• 800

• 1000

Adjustable via DIP switches or code

C13351

/

C14351

.

Process data

• max. 4 TPDOs with 1 ... 8 bytes

• max. 4 RPDOs with 1 ... 8 bytes

Parameter data

Max. 10 client and server SDO channels with 1 ... 8 bytes

Transfer mode for TPDOs

• With change of data

• Time-controlled, 1 to x ms

• After the reception of 1 to 240 sync telegrams

Voltage supply

Internal voltage supply of the communication module via the Servo Drive

9400.

Conformities, approvals

• CE

• UL

"Servo Drives 9400" hardware manual