3 residual hazards, Residual hazards, E94aycca communication manual (canopen®) – Lenze E94AYCCA User Manual

Page 13

Advertising
background image

EDS94AYCCA EN 5.0 - 06/2012

L

13

E94AYCCA communication manual (CANopen®)

Safety instructions

Device and application-specific safety instructions

 All works on and with Lenze drive and automation components may only be carried out

by qualified personnel. According to IEC 60364 and CENELEC HD 384 these are persons

who ...
– are familiar with installing, mounting, commissioning, and operating the product.
– have the qualifications necessary for their occupation.
– know and are able to apply all regulations for the prevention of accidents, directives

and laws that apply to the location of use.

2.2

Device and application-specific safety instructions

 During operation, the communication module must be securely connected to the

standard device.

 With external voltage supply, always use a separate power supply unit, safely

separated in accordance with EN 61800-5-1 in every control cabinet ("SELV"/"PELV").

 Only use cables that meet the given specifications.



Specification of the bus cable

( 27)

2.3

Residual hazards

Protection of persons

 If Servo Drives 9400 are used on a corner grounded system with a rated mains voltage

400V, external measures need to be implemented to provide reliable protection

against accidental contact.



Protective insulation

( 20)

Device protection

 The communication module contains electronic components that can be damaged or

destroyed by electrostatic discharge.



Installation

( 24)

Documentation of the standard device, control system, and plant/machine
All the other measures prescribed in this documentation must also be

implemented. Observe the safety instructions and application notes stated in

this manual.