C01122 | sync phase position, C01123 | sync tolerance, C01122 – Lenze E94AYCCA User Manual

Page 104: C01123, Is set higher than the sync cycle time, E94aycca communication manual (canopen®)

Advertising
background image

E94AYCCA communication manual (CANopen®)

Parameter reference

Communication-relevant parameters of the standard device

104

L

EDS94AYCCA EN 5.0 - 06/2012

C01122

C01123

Parameter | Name:

C01122 | Sync phase position

Data type: UNSIGNED_32

Index: 23453

d

= 5B9D

h

The phase position defines the zero point of time for the application relating to the synchronisation signal (bus

cycle). Since PDO processing is integrated in the system part of the application, the instant of the PDO acceptance

also changes if the phase position is changed.

• If 0 is set, the application is started together with the synchronisation signal.

• If a value > 0 is set, the application starts by the set time interval before the synchronisation signal arrives (the

phase position acts negatively).

Example:

If the phase position is set to 400 μs, the system part of the application starts 400 μs before the synchronisation

signal arrives.

From software version V3.0:

The effect of the sync phase position can be influenced by the application cycle set in

C01130

. For the Lenze setting

of

C01130

, the behaviour remains as before.



Synchronisation of PDOs via sync telegram ( 50)

Setting range

(min. value | unit | max. value)

Lenze setting

0

μs

64000 400 μs

;

Read access ; Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C01123 | Sync tolerance

Data type: UNSIGNED_32

Index: 23452

d

= 5B9C

h

Time slot for monitoring the synchronisation signal via the LS_SyncInput system block

• If the last synchronisation signal has been within this time slot around the expected value, the

SYNC_bSyncInsideWindow output of the LS_SyncInput system block is set to TRUE.

• This setting does not affect the synchronisation process.



Synchronisation of PDOs via sync telegram ( 50)

Setting range

(min. value | unit | max. value)

Lenze setting

0

μs

1000 0 μs

;

Read access ; Write access … CINH … PLC STOP … No transfer

Scaling factor: 1