E94AYCCA communication manual (CANopen®)

Parameter reference

Parameters of the communication module for slot MXI1

C13390

C13391

Parameter | Name:

C13390 | CAN Error Register (DS301V402)

Data type: BITFIELD_8

Index: 11185

d

= 2BB1

h

Mapping of the CANopen object

I-1001

(see DS301, V4.02)

Display range
0x00

0xFF

Value is bit-coded:

Information

Bit 0 Generic error

Currently only bits 0 and 4 contain the corresponding

information.

Bit 1 Current error (not used)
Bit 2 Voltage error (not used)
Bit 3 Temperature error (not used)
Bit 4 Communication error
Bit 5 Dev. prof. spec. err (not used)
Bit 6 Reserved
Bit 7 Manuf. spec. error (not used)

;

Read access … Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C13391 | CAN Emergency Object

Data type: BITFIELD_32

Index: 11184

d

= 2BB0

h

Identifier of the emergency telegram

• If bit 31 of this code is set (0x8nnnnnnn), the generation of emergency telegrams is deactivated.

• Mapping of the CANopen object

I-1014

(see DS301, V4.02).



Emergency telegram ( 84)

Setting range

Lenze setting

0x00000000

0xFFFFFFFF 0x00000081 (decimal: 129)

Value is bit-coded: (; = bit set)

Information

Bit 0 ; COB-ID bit 0
Bit 1 … COB-ID bit 1
Bit 2 … COB-ID bit 2
Bit 3 … COB-ID bit 3
Bit 4 … COB-ID bit 4
Bit 5 … COB-ID bit 5
Bit 6 … COB-ID bit 6
Bit 7 ; COB-ID bit 7
Bit 8 … COB-ID bit 8
Bit 9 … COB-ID bit 9

Bit 10 … COB-ID bit 10
Bit 11 … Reserved

... ...

Bit 30 … Reserved
Bit 31 … Emergency inactive/active

;

Read access ; Write access … CINH … PLC STOP … No transfer

Scaling factor: 1