I-1006 - Communication cycle period

Setting the sync telegram cycle time.

 A cycle time can be defined with the entry "1000" or an integer multiple of it.
 With "0 μs"

(Lenze setting), no sync telegrams are created.

 This object is related to the Lenze code

C00369

.

I-100C - Guard time

Monitoring time for node guarding.



Node guarding protocol

( 74)

 Time within the NMT slave expects the RTRs from the NMTmaster.
 The node life time is the product of the guard time and the life time factor:

Node Life Time = Guard Time (

I-100C

) x Life Time Factor (

I-100D

)

 The "life guarding event" occurs in the NMT slave if the slave has not been triggered by

the NMT master through an RTR within the node life time.

 With "0 ms"

(Lenze setting), monitoring is not supported by the slave.

 This object is related to the Lenze code

C13382

/

C14382

.

I-100D

Life Time Factor for node guarding.



Node guarding protocol

( 74)

 The node life time is the product of the guard time and the life time factor:

Node Life Time = Guard Time (

I-100C

) x Life Time Factor (

I-100D

)

 The "life guarding event" occurs in the NMT slave if the slave has not been triggered by

the NMT master through an RTR within the node life time.

 With "0"

(Lenze setting), monitoring is not supported by the slave.

 This object is related to the Lenze code

C13383

/

C14383

.

Index:

I-1006

Name:

Communication cycle period

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: Communication cycle period

0 μs

0

μs

65535000 rw

U32

Index:

I-100C

Name:

Guard time

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: Guard time

0 ms

0

ms

65535 rw

U16

Index:

I-100D

Name:

Life time factor

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: Life time factor

0

0

255 rw

U8