E94AYCCA communication manual (CANopen®)

Process data transfer

Synchronisation of PDOs via sync telegram

52

L

EDS94AYCCA EN 5.0 - 06/2012

Sync phase position
The phase position defines the zero point of time for the application relating to the

synchronisation signal (bus cycle). Since PDO processing is integrated in the system part of

the application, the instant of the PDO acceptance also changes if the phase position is

changed.

 If 0 is set, the application is started together with the synchronisation signal.
 If a value > 0 is set, the application starts by the set time interval before the

synchronisation signal arrives (the phase position acts negatively).

Example: If the phase position is set to 400 μs, the system part of the application starts

400 μs before the synchronisation signal arrives.

Sync tolerance
Time slot for monitoring the synchronisation signal via the LS_SyncInput system block.

 If the last synchronisation signal has been within this time slot around the expected

value, the SYNC_bSyncInsideWindow output of the LS_SyncInput system block is set to

TRUE.

 This setting does not affect the synchronisation process.

Sync-PLL increment
If the cycle times of the synchronisation signal and the phase-locking loop (PLL) differ from

each other, the setting in

C01124

defines the increment with which the phase-locking loop

can be readjusted.

 If the system bus (CANopen) is used as synchronisation source, the recommended time

increment for deviations is 109 ns (Lenze setting).

Note!

From Servo Drive 9400 software version V3.0:

The effect of the sync phase position can be influenced by the application cycle

set in

C01130

. For the Lenze setting of

C01130

, the behaviour remains as before.