Rockwell Automation 1752-L24BBBE SmartGuard 600 Controllers User Manual User Manual

Page 277

Advertising
background image

Rockwell Automation Publication 1752-UM001E-EN-P - June 2014

277

Application and Configuration Examples

Appendix F

Figure 103 - Wiring Diagram

Figure 104 - Configuration

I1

I0

I3

I5

I2

I4

I6

I7

I9

I8

I11

I13

I10

I12

I14

I15

V1

G1

T0

T1

T2

T3

O1

O0

V2

G2

O3

O5

O2

O4

O6

O7

M

KM1

KM2

KM1-NC

KM2-NC

KM1 KM2

E1

E2

S1

S2

+

A1

S12 S22 Y2

14

24 Y32

14

A1

24

Y32

S11 S21 S34

A2

-

MatGuard Mats

Connect a 24V dc power supply to terminals V0 and G0, the
power supply terminals for internal circuits.

E1 and E2: 24V dc Power Supplies
S1: Reset Switch
S2: Emergency Stop Push Button
KM1 and KM2: Contactors

Power Supply

Control Circuit

MSR30RT/RTP

White

Black

Black

White

Advertising