Rockwell Automation 1752-L24BBBE SmartGuard 600 Controllers User Manual User Manual
Page 97
![background image](/manuals/579479/97/background.png)
Rockwell Automation Publication 1752-UM001E-EN-P - June 2014
97
Configure Your Controller for DeviceNet Communication
Chapter 7
7.
To add local I/O monitor data for Input types, check the appropriate
Local I/O Monitor checkbox.
Output types cannot include local I/O monitor data. You can read only
input and output values; you cannot directly write to them.
8.
Click New to create an I/O tag.
Multiple I/O tags can be defined in an I/O assembly. I/O tags for up to 16
bytes can be defined in each I/O assembly. The I/O tags defined here can
be used in the Logic Editor.
9.
Type a name for the tag and click the type: BOOL, BYTE, WORD, or
DWORD.
10.
Click OK.
Tag Name
Data Size
Attribute Type
Local Input Monitor 1 (Inputs 0…7)
Byte
Non-safety
Local Input Monitor 2 (Inputs 8…15)
Byte
Non-safety
Local Output Monitor (Outputs 0…7)
Byte
Non-safety